From: "B2"
Date: Thu, 7 Sep 2000 23:38:27 -0400
Subject: Re: [TSSP] Low Q Values
Hi Mark, I see that the Rdc values for the close wound coil are smaller than = the Rdc values for the space wound coil. Were these different sized = forms? Cheers, Barry ----- Original Message -----=20 From: "Mark S. Rzeszotarski, Ph.D."To: Sent: Thursday, September 07, 2000 6:49 AM Subject: Re: [TSSP] Low Q Values > Hello All: > I have attached an ASCII file which looks at the contributions = of > skin effect and proximity effect to the effective resistance of a = coil, > using Malcolm's excellent data from a few years ago. I did the calcs = back > in 1996, but I think they are correct. For your perusal and = interpretation. > Regards, >=20 -------------------------------------------------------------------------= ------- > Mark S. Rzeszotarski, Ph.D., MetroHealth Medical Center,Radiology > Department, Cleveland OH 44109-1998 >=20
Maintainer Paul Nicholson, paul@abelian.demon.co.uk.