Hi All,

A correction...

>I measured the Q of my coil using the Q=Fo/BW formula and based that on the 
>measured RMS input current.  The Q was 59.25  (146.34 / (147.61-145.14)).
>
>With an input voltage of 0.6606 RMS, I would expect the top voltage to be:
>0.6606 x 1.414 x 59.25 = 55.35 volts.
>
>The sum I measured is 69.72 volts.  

I don't trust the method I used above and I remembered my coil really has a
Q around 70.  I remeasured the Q with an antenna and scope.  And got a Q of
67.47.  That is incredibly close to the 69.72 volts the profile test gave!

Cheers,

	Terry