TSSP: List Archives

From: "Terrell W. Fritz"
Date: Sat, 21 Oct 2000 23:13:18 -0600
Subject: [TSSP] correction Q correction - NSVPI - Latter Results

Hi All,

>A correction...
>
>>I measured the Q of my coil using the Q=Fo/BW formula and based that on the 
>>measured RMS input current.  The Q was 59.25  (146.34 / (147.61-145.14)).
>>
>>With an input voltage of 0.6606 RMS, I would expect the top voltage to be:
>>0.6606 x 1.414 x 59.25 = 55.35 volts.
>>
>>The sum I measured is 69.72 volts.  
>
>I don't trust the method I used above and I remembered my coil really has a 
>Q around 70.  I remeasured the Q with an antenna and scope.  And got a Q of 
>67.47.  That is incredibly close to the 69.72 volts the profile test gave!
>
>Cheers,
>
>	Terry

Actually, if I plug the new Q into the equation above I get a voltage of
63.023.  So I have a little healthy error :-))

Also, my oscilloscope is a Tektronix TDS210 not a B210.

Picky tonight :-))

Cheers,

	Terry



Maintainer Paul Nicholson, paul@abelian.demon.co.uk.