From: Paul
Date: Mon, 25 Dec 2000 17:51:13 +0000
Subject: Re: [TSSP] Capacitance between primary and secondary
Terrell W. Fritz wrote:
> The primary and secondary coils were floating. There was no
> connection to the ground plane. Just the two coils with the
> meter in between.
Yep, that's taken account of. If the secondary where connected
to the ground plane it would short out the 22.5pF cap to
leave, at 0 inches,
26.7 | 24.0 = 50.7 pF
between primary and secondary. Hence my reason for asking if
secondary was grounded.
| |
| |
| |
| | secondary
| |
| |
| | primary
| | - 26.7pF - * * * * * * *
| |
22.5pF 24.0pF
| |
__________________________________________
ground plane
Cheers,
--
Paul Nicholson,
Manchester, UK.
--
Maintainer Paul Nicholson, paul@abelian.demon.co.uk.