Hi Paul,

Thanks for the demensions.  I set it up and ran it and got 9200 Volts/cm
with 400kV on the toroid.

http://hot-streamer.com/temp/MarcoCoil/Marco-a.gif

The data files are at:
http://hot-streamer.com/temp/MarcoCoil/

That is a little short of the 26kV/cm we were looking for.  I have not used
the  stress stuff much but I think it works properly.  There could be a bug
in it...  Or the grid is too choppy to show the actual tiny stresses at the
surface.

Cheers,

	Terry


At 12:27 AM 5/26/2001 +0100, you wrote:
>Terrell W. Fritz wrote:
>
>> I have no idea how much space there is between to top of Marco's secondary
>> and the centerline of his toroid so I am guess there.  I think I got the
>> toroid cord diameter wrong too...
>
>Chord looks a little small, I use
>
>toroid {
>   outer_radius 0.7575  ; Distance from center to outer rim.
>   inner_radius 0.5575  ; Distance from center to inner rim.
>   altitude 2.85        ; Distance of center above ground plane.
>}
>
>ie, a chord of 20cm, 
>
>secondary {
>   radius 0.20        ; Radius of coil
>   length 1.575       ; Length of coil
>   altitude 0.995     ; Distance of base of coil above ground plane.
>   inductance 0.0802  ; The measured inductance, for info only.
>;; use_lundin     ; Ignore the given inductance and use the lundin
>formula
>   turns 939
>   resistance 11.2      ; Measured resistance at DC.
>   conductor_radius 0.725e-3
>}
>
>From top of secondary to plane of toroid is 
> 2.85 - (0.995 + 1.575) = 28cm
>
>So chord = 7.874", top of coil to toroid = 11.02"
>--
>Paul Nicholson,