From: "Barton B. Anderson"
Date: Fri, 27 Sep 2002 17:38:48 -0700
Subject: Re: [TSSP] Top Voltage
Hi Paul, Paul wrote: > Could it be that streamers are > forming at around the expected breakout voltage My assumed understanding of the 26kv/cm was I guess set on the North Report, in that, this value was the value of "corona inception". The spark itself breaking out would have to occur following this corona inception voltage. It is then only dependent on a value after 26kV/cm. Anyway, that was always my understanding. Has everyone else thought differently? Bart
Maintainer Paul Nicholson, paul@abelian.demon.co.uk.