From: Paul
Date: Sun, 13 Oct 2002 15:35:55 +0100
Subject: Re: [TSSP] F A N T C: - It's NEW! - and needs some TSSP input
I wrote: > S E L E C T F R E Q O R C A P A C I T A N C E A N A L Y S I S > X Ces X Ces (topload in-situ) X Ces (coil to coil) > Secondary Voltage Profile: X Loaded X Bare X Linear X DC > [RUN BUTTON] Of course, I should have left out F R E Q in the heading. Bart wrote: > Computing ..... please wait > Secondary Resonant Frequency: 238.22 kHz > Gap open = 238kHz Nice agreement, but not typical at the details setting of 1. Compared with tssp we get: fantc tssp meas f1 238.22 kHz 234.9 kHz 238 kHz Lee 18.23 mH 18.44 mH Les 18.55 mH 18.69 mH Ldc 19.28 mH 18.84 mH 18.67 mH Cee 23.45 pF 24.23 mH Ces 24.42 pF 24.57 mH Cdc 36.46 pF 37.50 mH so a little out, and we'd expect fantc to converge towards tssp as the detail setting is raised. -- Paul Nicholson, --
Maintainer Paul Nicholson, paul@abelian.demon.co.uk.