TSSP: List Archives

From: Greg Leyh
Date: Mon, 21 Oct 2002 23:06:21 -0700
Subject: Re: [TSSP] F A N T C: - It's NEW! - and needs some TSSP input

At 04:29 AM 10/21/2002, Paul wrote:

>Greg wrote:
> > For a single-turn coil 20ft in diameter with a 0.1" dia conductor:
> > The Wheeler formulas yield 30uH and 26.6uH respectively.
> > The Maxwell 3D 9.0 field simulator yields 51uH.
>
> > Does this coil have proportions that incur high calculation errors?
>
>No, should come out pretty accurately, around 31uH.
>
> > Inside = 240
> > Outside = 240.1
>
>Enter half these values, fantc is expecting the radius.


My apologies!
FANTC gives 30.71uH when I input the numbers *correctly*.
Sorry to bother you with such a non-problem.



Maintainer Paul Nicholson, paul@abelian.demon.co.uk.